Glaucoma Research - Cataracts, Surgery, Treatment, Blindness

Glaucoma Research Today is a free monthly online journal that collates and summarizes the latest research about Glaucoma, including details on cataracts, surgery, treatment, blindness.


Glaucoma Research Today

Home

View Latest Issue

Information About Glaucoma

Books on Glaucoma

Advertising in Research Today

View Other Research Today Publications



Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in tilted disk.

Yu S, Tanabe T, Hangai M, Morishita S, Kurimoto Y, Yoshimura N

Department of Ophthalmology and Visual Sciences, Kyoto University, Kyoto, Japan.

PURPOSE: To determine whether scanning laser polarimetry with variable corneal compensation (GDx-VCC) or optical coherence tomography (OCT) is helpful for the analysis of the retinal nerve fiber layer (RNFL) thickness in glaucoma subjects with tilted disk. DESIGN: Retrospective case-control study. METHODS: We included 21 glaucomatous eyes with tilted disk and 35 glaucomatous eyes without tilted disk. Peripapillary RNFL thickness measurement by GDx-VCC and OCT, and also visual field testing with a Humphrey Field Analyzer program 30-2 (HFA) were performed in all subjects. RESULTS: In the group without tilted disk, the RNFL thickness values obtained with GDx-VCC and OCT analysis had a good correlation with mean deviation (MD), and clearly showed stage-dependent reduction. Conversely, in the group with tilted disk, a discrepancy in the RNFL measurement between GDx-VCC and OCT was observed. The correlation of RNFL measurement to the visual field was further examined at each hemifield (superior and inferior). In the group without tilted disk, the measurements of both instruments at each hemifield were in good correlation with the mean pattern deviation values. However, in the group with tilted disk, the GDx-VCC derived values did not correlate with the visual field defect in both hemifields, whereas OCT was in good association with both mean pattern deviation values. Infrared images acquired with a wavelength of nearly 780 nm revealed a high reflex from the sclera in the tilted disk. CONCLUSIONS: Our study has suggested that RNFL analysis by OCT is more suitable for the glaucoma assessment in the tilted disk compared with GDx-VCC.

Published 28 August 2006 in Am J Ophthalmol, 142(3): 475-82.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Glaucoma Research Today. All Rights Reserved.



Glaucoma Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Glaucoma Books

Glaucoma Medical Therapy: Principles and Management (Ophthalmology Monographs)

Glaucoma Medical Therapy: Principles and Management (Ophthalmology Monographs)