Glaucoma Research - Cataracts, Surgery, Treatment, Blindness

Glaucoma Research Today is a free monthly online journal that collates and summarizes the latest research about Glaucoma, including details on cataracts, surgery, treatment, blindness.


Glaucoma Research Today

Home

View Latest Issue

Information About Glaucoma

Books on Glaucoma

Advertising in Research Today

View Other Research Today Publications



Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by optical coherence tomography.

Ajtony C, Balla Z, Somoskeoy S, Kovacs B

Department of Ophthalmology, University of Pécs Medical and Health Sciences Center, Pécs, Hungary. csilla.ajtony@aok.pte.hu

PURPOSE: To evaluate the strength and pattern of the relationship between visual field (VF) sensitivity and retinal nerve fiber layer (RNFL) thickness as measured by StratusOCT (Carl Zeiss Meditec, Inc., Dublin, CA). METHODS: Three hundred eleven subjects--45 normal, 102 with preperimetric glaucoma (PPG), and 164 with primary open-angle glaucoma (POAG)--were enrolled in this cross-sectional study. The relationship between RNFL thickness and VF sensitivity, expressed as mean deviation (MD) and mean sensitivity (MS), were evaluated with linear and nonlinear regression models, and the coefficient of determination (R(2)) was calculated. The association between RNFL/VF was described by bivariate Pearson correlation coefficients. RESULTS: The correlation of RNFL and the VF parameters MS and MD in normal and PPG eyes was not significant. In POAG eyes, RNFL and both MS (r = 0.733) and MD (r = 0.718) correlated significantly. Linear regression plots of MS or MD against RNFL thickness demonstrated a negligible degree of determination in normal (R(2) = 0.0378 and 0.0121, respectively) and PPG groups (R(2) = 0.0215 and 0.0151, respectively), whereas their relationship fit a curvilinear regression model (R(2) = 0.6947 and 0.723) in the POAG group. Receiver operating characteristic (ROC) curves describing the VF parameters and average RNFL thickness (AVG) were evaluated to differentiate PPG from POAG eyes. Repeated analysis with the best-performing test parameter, pattern standard deviation (PSD) (AUROC = 0.937) with a cutoff of 1.9 dB, showed that regression profiles in the POAG group with PSD >1.9 dB maintained a strong curvilinear RNFL/VF relationship, whereas those with PSD <1.9 dB exhibited a relationship almost indistinguishable from the PPG group. CONCLUSIONS: Evaluation of the structure-function relationship in normal subjects and those with PPG or POAG showed strong curvilinear regression in POAG eyes with PSD >1.9 dB and RNFL AVG thickness below 70 microm, whereas no correlation was detectable above these values.

Published 1 January 2007 in Invest Ophthalmol Vis Sci, 48(1): 258-63.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Glaucoma Research Today. All Rights Reserved.



Glaucoma Research Today Archive:

Volume 1 (2005)
  Issue 1 (November)
  Issue 2 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)



Glaucoma Books

Glaucoma Medical Therapy: Principles and Management (Ophthalmology Monographs)

Glaucoma Medical Therapy: Principles and Management (Ophthalmology Monographs)